HPLC Columns and Cartridges
Filtered Search Results
Restek™ Ultra™ IBD (Alkyl Amide) Mixed Mode HPLC Column, 5 μm, 4.6 mm x 30 mm
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Column Format: Analytical Column; Carbon Load: 12%; Pore Size: 100 Å; Column Phase: Reversed Phase and HILIC
Thermo Scientific™ EASY-Spray™ HPLC Columns
Robust capillary flow HPLC columns for sensitive protein, peptide and mAbs separation using the stand alone or integrated easy to use design.
| Phase | Reversed Phase |
|---|
Thermo Scientific™ ProSwift™ RP-1S PSDVB Reversed Phase HPLC Column, Monolith, 4.6 mm x 50 mm
Column Format: Analytical Column; Pore Size: Monolith; Column Phase: Reversed Phase
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ DNAPac™ PA200 Oligonucleotide HPLC Columns
Enjoy strong anion exchange for high-resolution analysis and purification of synthetic oligonucleotides with Thermo Scientific™ DNAPac™ PA200 Oligonucleotide HPLC Columns.
| Pore Size | Nonporous |
|---|---|
| Stationary Phase | Quaternary Ammonium |
| Temperature | 85°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| Quantity | Each |
| Green Features | Responsibly packaged |
| Technique | Bio-LC |
| Product Line | DNAPac |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns
Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
| Temperature | 50°C |
| Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
| Endcapped | Proprietary |
| Column Type | Mixed Mode |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
| USP Type | L85 |
Thermo Scientific™ Syncronis™ Amino HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Thermo Scientific™ Syncronis™ Amino LC Columns.
| Pore Size | 100 Å |
|---|---|
| Carbon Load | 4% |
| Stationary Phase | Amino (NH2) |
| Temperature | 60°C |
| Phase | Reversed Phase, Normal Phase, Ion Exchange, HILIC |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Column Type | Mixed Mode |
| pH | 2 to 8 |
| Surface Area | 320 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| USP Type | L8 |
Thermo Scientific™ Acclaim™ Mixed Mode WAX-1 HPLC Columns
When you need powerful selectivity control for the separation of anionic molecules, use Thermo Scientific™ Acclaim™ Mixed-Mode WAX-1 LC columns.
| Pore Size | 120 Å |
|---|---|
| Phase | Reversed Phase, Ion Exchange, HILIC |
| Column Type | Mixed Mode |
| pH | 2.5 to 7.5 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
| USP Type | L78 |
Thermo Scientific™ µPAC™ Neo HPLC Columns
Learn more about your proteome samples with Thermo Scientific™ μPAC™ Neo Plus HPLC columns.
| Pore Size | 100 to 300 Å |
|---|---|
| Stationary Phase | C18 |
| Endcapped | Yes |
| Packing Material | Silicon Chip |
| pH | 1.5 to 7 |
| Max. Pressure | 6526 psi (450 bar) |
Thermo Scientific™ Hypersil™ ODS-2 C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes separated under difficult operating conditions.
| Pore Size | 80 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous Type A Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| Product Line | Hypersil Classical |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ 120 C8 HPLC Columns
Achieve exceptional performance and maximum resolution for reversed-phase separation of analytes with moderate hydrophobicity.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C8 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L7 |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 18% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil Drop-In Guard Cartridges —C18, C8, C1, Silica
Convenient, economical, and effective protection for extending column lifetimes
| Pore Size | 120Å |
|---|---|
| Length (Metric) | 10 mm |
| Endcapped | Yes |
| For Use With (Equipment) | Hypersil™ HPLC Column |
| Particle Shape | Spherical |
Thermo Scientific™ DNAPac™ PA100 Oligonucleotide HPLC Columns
Features strong anion-exchange resin for high-resolution analysis and purification of synthetic and modified oligonucleotides.
| Pore Size | Nonporous |
|---|---|
| Particle Size | 13 μm |
| Stationary Phase | Quaternary Ammonium |
| Temperature | 90°C |
| Column Type | Ion Exchange |
| pH | 2 to 12.5 |
| Quantity | Each |